Loop Electrodes

Loop Electrodes

Loop electrodes remove tissue in one smooth pass, cutting and sealing at the same time. They are best known for LEEP (loop electrosurgical excision procedure), also called LLETZ, the standard treatment for abnormal cervical cells. Medfort loop electrodes come in a range of sizes (codes SI-111901 to SI-111912).

Where they are used

They are used for LEEP/LLETZ cervical excision and conization, and for shaving and removing skin lesions in dermatology and plastic surgery.

Our range

  • Loop electrodes in a range of widths and depths
  • Several wire diameters
  • Fits standard electrosurgical pencils

Material and finish

Electrosurgical instruments are made from high-grade stainless steel with a durable insulation coating, leaving only the working tip exposed. Connectors are machined to fit standard US and European cables. Non-stick versions have a special tip alloy or coating that cuts tissue sticking and charring. Handles are shaped for a comfortable, secure grip, and tips are polished so tissue releases cleanly after each activation. Bipolar forceps are made with a spring tension that lets the surgeon open and close the tips precisely with light finger pressure.

How to choose

Choose the loop size to cover the lesion or the transformation zone in one pass where possible. Smaller loops suit small lesions and young women, where tissue should be preserved. Larger loops remove a bigger area at once. Use the settings recommended by your generator manufacturer.

Quality control

Every electrosurgical instrument is checked for continuity and insulation integrity, and the tips are inspected for alignment. Connectors are test-fitted to standard cables. Each item is cleaned and packed so the insulation and tips are protected in transit.

Safety checks

Before every operation, inspect the insulation along the whole shaft for cracks, nicks or worn areas, and check that the connector fits firmly. Damaged insulation can cause burns away from the tip that the surgeon cannot see. Replace any instrument or cable that fails inspection.

Care and sterilization

Check the insulation before every use, and do not use an instrument if the coating is cracked or damaged. Clean the tips gently with a soft cloth or sponge, never with abrasive pads, and flush irrigation channels after use. Reusable instruments and cables are suitable for steam sterilization. Single-use items are for one patient only.

Ordering and custom sizes

You can order single instruments, mixed quantities or complete sets, and we supply hospitals, clinics, distributors and government tenders. If you need a pattern, length or size that is not listed, send us a drawing, a sample or a catalogue reference and we will quote for it. We also offer OEM and private label manufacturing, with your logo laser-etched on the instrument and your own packaging. Please contact us for prices, delivery times and shipping to your country.

Frequently asked questions

Are loop electrodes reusable? Please ask us about reusable and single-use options.

Do I need a special pencil? No. Loop electrodes fit standard electrosurgical pencils.

Why choose Medfort

  • Manufactured in Sialkot, Pakistan, the world's centre of surgical instrument making
  • Surgical grade stainless steel to AISI, ASTM and DIN standards
  • ISO 9001, ISO 13485 and CE marked manufacturing
  • OEM and private label manufacturing available
  • Single instruments, bulk orders and complete sets

Need a quote, a custom size or a complete set? Email [email protected] or call +92 349 0444976.